Sample Rate Converters |
|
---|---|
Sample Rate Lock Range |
41 to 216 kHz (MADI) |
Gain Error |
-0.01 dB |
Dynamic Range |
> 139 dB (-60 dBFS method) |
THD + N |
< -130 dB (0.00003%); 0 dBFS input |
Latency |
43 to 196 samples (Network and MADI sample rate dependent) |
MADI Clock Sources |
RedNet, MADI Input and Word Clock |
Digital Performance |
|
---|---|
Supported Sample Rates |
44.1 / 48 / 88.2 / 96 / 176.4 / 192 kHz (-4% / -0.1% / +0.1% / +4.167%) at 24 bit |
Clock Sources |
Internal, MADI or from Dante Network Leader |
Ext. Word Clock Range |
Nominal sample rate ±7.5% |
Rear Panel Connectivity |
|
---|---|
MADI Coaxial |
|
Electrical Standard |
As per AES10:2008 |
Recommended Cable |
75Ω characteristic impedance |
Connector |
BNC 75Ω |
MADI Optical |
|
Optical Standard |
As per AES10:2008 (ISO/IEC 9314-3, FDDI, ANSI X3.166) |
Recommended Cable |
(OM1) Multi-mode, Graded-index, 62.5μm core, 125μm cladding (OM2) Multi-mode, Graded-index, 50μm core, 125μm cladding OM1 adheres to AES10:2008 RedNet 6/D64R supports OM2 if 3rd Party Device also supports OM2. |
Connector |
Duplex SC |
Word Clock |
|
Input |
1 x BNC 75Ω port (switchable termination) |
Output |
1 x BNC 75Ω port |
PSU and Network |
|
PSU |
1 [2] x IEC Inputs with retaining clips |
Network |
1 x RJ45 [2 x etherCON NE8FBH-S, also compatible with standard RJ45 connectors (Accomodates rugged etherCON NE8MC*. Does not intermate with Cat 6 cable connector NE8MC6-MO and NKE65* cable)] |
Front Panel Indicators |
|
---|---|
Power [PSU A] |
Green LED. Illuminates when an AC input is applied and all DC outputs are present |
PSU B [D64R only] |
Green LED. Illuminates when an AC input is applied and all DC outputs are present |
Network Connected [Primary] |
Green LED. Indicates that a network connection is present [on Primary port when in Redundant mode. When in Switched mode, a valid network connection at either Primary or Secondary network port will cause this LED to illuminate] |
Network Secondary [D64R only] |
Green LED. Indicates that a network connection is present on secondary port when in redundant mode. Not used in switched mode |
Network Locked |
Green LED. When unit is network follower, shows valid network lock. When unit is network leader, shows lock to indicated clock source. Flashing indicates external clock is selected but not connected |
Sample Rate |
Orange LED for each: 44.1 kHz, 48 kHz, x2, x4 |
Pull Up/Down |
Indicates unit is set to operate on a Dante pull up/down domain |
RedNet Clock Source |
Orange LED for each: Internal, MADI Input and Word Clock |
MADI Input |
Orange LED for each: Coaxial, Optical [and Auto] |
MADI Clock Source |
Orange LED for each: [SRC], RedNet, MADI Input and Word Clock |
MADI Status [RedNet 6] |
Orange LED for each: SRC & O/P Varispeed |
Signal [D64R only] |
2 Green LEDs: 1 input/1 output. Illuminate at -126 dBFS. Orange LED: Varispeed |
Network Modes [D64R Only] |
|
---|---|
Redundant |
Allows unit to connect to two independent networks |
Switched |
Connects both ports to integrated network switch allowing daisy-chaining of device |
Channel Count |
|||
---|---|---|---|
MADI Clock |
RedNet Clock: |
||
Single |
Double |
Quad |
|
Single |
64 |
32 |
16 |
Single – Varispeed |
56 |
32 |
16 |
Double |
32 |
32 |
16 |
Double – Varispeed |
28 |
28 |
16 |
Quad |
16 |
16 |
16 |
Quad – Varispeed |
14 |
14 |
14 |
Power |
|
---|---|
PSU(s) |
1 [2] x Internal, 100-240V, 50/60Hz, consumption 30W |