Your RedNet A16R MkII may require a firmware update when it is first installed and switched on. Firmware updates are initiated and handled automatically by the RedNet Control 2 application.
Important
You must not interrupt the firmware update procedure – either by switching off power to the RedNet A16R MkII unit or the computer on which RedNet Control 2 is running, or by disconnecting either from the network.
From time to time, we release RedNet firmware updates within new versions of RedNet Control 2. We recommend keeping all RedNet units up to date.
Each RedNet A16R MkII will automatically lock to a valid Network Leader via its Dante connection. Alternatively, if a Network Leader is not present, then the unit can be chosen as the Network Leader by the user. Also, see Clock Source.
RedNet A16R MkII is able to operate at a specified pull-up or pull-down percentage as selected in the Dante Controller application.
SRC will need to be switched in if the AES3 source is not using the current system clock as a reference signal.
Note
Engaging the sample rate converter increases the overall latency of the device.
You can control the attenuation for all analogue and digital I/O channels individually by up to 78dB in 1dB steps via RedNet Control 2. You can also mute or dim each channel; Dim attenuates a channel by 20dB.
The global analogue I/O operating level can be either 18 or 24dBu at 0dBFS. You can set this in the RedNet Control Tools menu.